Customize
About Item
Power Quality & Protection Services ensure stable, safe, and disturbance-free power supply for tissue culture laboratories, polyhouses, cold storage units, and agri processing facilities.
Voltage fluctuation, harmonics, and poor grounding can damage sensitive equipment like:
PCR systems
HVAC controllers
Incubators
Automation panels
Solar inverters
This service protects infrastructure, reduces downtime, and increases equipment lifespan.
š§ Detailed Service Scope
1ļøā£ Harmonic Analysis
Assessment of electrical power quality to detect distortion:
Total Harmonic Distortion (THD) measurement
Phase imbalance analysis
Neutral current evaluation
Power factor assessment
Load waveform monitoring
Identification of harmonic-generating loads
Deliverable:
Power Quality Analysis Report
Harmonic mitigation recommendation
Prevents:
ā Overheating
ā Transformer stress
ā Equipment malfunction
2ļøā£ Voltage Stabilizer Installation
Installation of industrial stabilizers to maintain constant voltage:
Input-output voltage monitoring
Automatic voltage correction
Stabilizer capacity sizing
Panel integration
Protection against under/over voltage
Ideal for rural grid fluctuation areas.
3ļøā£ Servo Stabilizer Setup
Advanced servo-controlled stabilizer installation:
Microprocessor-based control
High-precision voltage correction
Three-phase balancing
Automatic bypass integration
Load-based configuration
Recommended for:
Tissue Culture Labs
Analytical Lab Equipment
Cold Storage Compressors
4ļøā£ Surge Protection System
Protection against voltage spikes and lightning-induced surges:
Surge Protection Device (SPD) installation
Type 1 & Type 2 SPD integration
Lightning surge suppression
Panel-level surge protection
Earthing system integration
Protects:
ā Solar systems
ā UPS output lines
ā Lab electronics
5ļøā£ Earthing Pit Installation
Grounding system for safe power distribution:
Copper plate / pipe earthing
Chemical earthing (if required)
Dedicated UPS earthing
Earth resistance testing
Ground grid planning
Target Earth Resistance:
< 1ā2 Ohms (as per industrial norms)
Prevents:
ā Electrical shock
ā Equipment damage
ā Fire hazards
6ļøā£ Thermal Scanning of Panels
Infrared thermal inspection to detect electrical faults:
Hotspot identification
Loose connection detection
Overloaded breaker detection
Busbar overheating analysis
Preventive maintenance reporting
Deliverable:
Thermal imaging report
Risk assessment document
Preventive action recommendation
Reduces risk of unexpected electrical failure.
š¦ Deliverables
Harmonic analysis report
Voltage stabilization design sheet
Earthing test certificate
Thermal scanning report
Surge protection layout diagram
Commissioning & safety compliance report
šÆ Ideal For
Tissue Culture Laboratories
Agri Biotechnology Units
Polyhouse & Greenhouse Projects
Cold Storage Facilities
Seed Processing Units
Solar-Integrated Farms